LHSH manufactures commercial fire rated glass doors that combine fire compartmentation with clear visibility through corridors, entrances and shared building spaces.
Unlike a conventional solid fire door, a glazed fire door allows occupants, staff and security personnel to see through the opening while maintaining the required fire separation performance when the correct fire-rated glazing, door leaf, frame, seals and hardware are specified as a complete system.
As a glass fire rated door manufacturer in China, LHSH can support project-specific requirements including fire rating, door dimensions, glazing configuration, frame design, finish, hardware and opening direction.
Why Choose Fire Rated Glass Doors Instead of Solid Fire Doors?
A fire rated glass door is especially useful when a project needs both compartmentation and visual communication between spaces.
● Improve visibility through corridors, entrances and controlled-access areas.
● Allow staff to check activity on the opposite side of the door before opening.
● Support safer pedestrian circulation in hospitals, schools and public buildings.
● Introduce natural light into enclosed corridors and interior building zones.
● Maintain a more open architectural appearance compared with fully solid fire doors.
● Support fire compartmentation when the door, frame, glazing and associated components are correctly specified as a tested assembly.
For this reason, commercial fire rated glass doors are commonly selected for areas where both life safety and visibility matter.
Fire Rated Glass Door Configurations Available from LHSH
LHSH provides different glazed fire door configurations according to opening width, traffic conditions and architectural requirements.
Single-Leaf Fire Rated Glass Door
Suitable for standard pedestrian openings such as corridors, offices, classrooms, hotel areas and equipment-room entrances.
● Compact configuration for standard openings
● Available with fire-resistant vision glazing
● Suitable for inward or outward swing requirements
● Hardware can be configured according to the project
Double-Leaf Fire Rated Glass Door
Designed for wider openings and locations with higher pedestrian or equipment traffic.
● Provides greater clear opening width
● Suitable for public buildings and commercial corridors
● Can incorporate fire-rated glazing in one or both leaves
● Panic hardware and door closers can be specified where required
Unequal-Leaf Fire Rated Glass Door
Suitable when a normal daily pedestrian opening is required together with occasional wider access.
● Main leaf used for normal traffic
● Secondary leaf opened when additional width is required
● Suitable for hospitals, commercial buildings and public facilities
● Combines functional access with fire separation
Fully Glazed or Large-Vision Fire Door
For projects requiring increased transparency, LHSH can review large glazed or fully glazed fire door configurations according to the required fire rating and tested system design.
The allowable glazing area should always be confirmed against the required certification and complete door assembly rather than selected purely according to appearance.
LHSH Fire Rated Glass Door Technical Options
LHSH currently provides multiple technical configurations for fire rated glazed door projects.
● Door Material: Galvanized steel
● Door Leaf Steel Thickness: approximately 1.0–1.2 mm depending on configuration
● Door Frame Steel Thickness: approximately 1.5–2.0 mm depending on configuration
● Fire Rating Options: EI30 / EI60 / EI90 / EI120
● Fire Resistance Range: project configurations from approximately 20 minutes up to 180 minutes are available subject to applicable system and standard
● Door Configuration: Single / Double / Unequal Leaf
● Opening Direction: Inward / Outward
● Glazing: Fire-resistant glass
● Vision Panel: Available according to project requirements
● Surface Finish: Powder coated
● Color: RAL colors and customized finishes
● Hardware Options: Lock, handle, fire-rated hinges, door closer, panic bar and other project-specified hardware
● Frame Configuration: Customizable according to the opening and project requirements
The final specification should always be confirmed according to the target certification, required fire rating and approved project drawings. LHSH publishes EN, BS and GB-related fire performance configurations across its current fire door range.
EI30, EI60, EI90 or EI120: Which Fire Rated Glass Door Should You Choose?
The required fire rating should be determined by the building code, fire strategy, consultant specification and door schedule for the project.
EI30 Fire Rated Glass Door
Provides 30 minutes of integrity and insulation performance when specified as an applicable tested system.
Often considered for internal compartment openings where a 30-minute rating is required by the project.
EI60 Fire Rated Glass Door
Provides 60 minutes of fire resistance under the corresponding tested classification.
Commonly specified for commercial corridors, building compartments and protected access routes requiring a higher level of separation.
EI90 Fire Rated Glass Door
Designed for applications requiring 90 minutes of fire resistance.
May be specified in higher-risk building zones or infrastructure projects depending on local requirements.
EI120 Fire Rated Glass Door
Provides a higher level of fire separation where a 120-minute EI classification is required.
Suitable applications depend on the approved fire strategy and certified door configuration.
The highest available rating should not automatically be selected. Buyers should match the door to the actual requirement shown on the approved fire door schedule.
Custom Fire Rated Glass Doors for Commercial Projects
LHSH can manufacture glazed fire doors according to project-specific requirements rather than relying only on standard catalogue configurations.
Glass Size and Position
● Small vision panels for basic corridor visibility
● Vertical viewing panels
● Larger glazed sections where the certified system permits
● Customized positioning according to architectural drawings
Door Dimensions
● Project-specific width and height
● Single-leaf configurations
● Double-leaf configurations
● Unequal-leaf configurations
Door Frames
● Frame dimensions coordinated with wall thickness
● Custom frame configurations
● Steel frame options for different installation conditions
Surface Finish
● Powder-coated finishes
● RAL color selection
● Woodgrain finish options for selected configurations
● Project-specific architectural finishes
Hardware
● Fire-rated hinges
● Door closers
● Locks and handles
● Panic bars
● Access control preparation
● Other hardware according to approved project requirements
Where Are Commercial Fire Rated Glass Doors Used?
Commercial Buildings
● Office corridors
● Shopping centers
● Hotels
● Mixed-use developments
● Building lobbies
Hospitals and Healthcare Facilities
Visibility is especially valuable in healthcare environments where staff need to monitor corridor traffic and movement between controlled areas.
● Hospital corridors
● Clinical departments
● Staff access areas
● Public circulation areas
Schools and Educational Facilities
Vision panels can help improve awareness of pedestrian traffic while preserving required fire compartmentation.
● Classrooms
● Corridors
● Libraries
● Universities
● Educational facilities
Transportation Infrastructure
LHSH also manufactures specialist fire door products for rail transit applications.
Typical glazed door applications can include:
● Metro stations
● Railway facilities
● Transport terminals
● Passenger circulation areas
● Service corridors
Government and Public Buildings
● Museums
● Libraries
● Stadiums
● Government offices
● Public service buildings
Industrial Projects
● Control rooms
● Equipment areas
● Production facilities
● Fire compartment entrances
● Utility areas
Why Choose LHSH as Your Glass Fire Rated Door Manufacturer in China?
Fire Protection Experience Since 1998
LHSH was established in 1998 and specializes in the research, design, manufacturing and service of fire doors, fire windows and fire-resistant building products.
20,000+ m² Production Base
LHSH operates from a production base exceeding 20,000 square meters and manufactures fire doors, fire windows, fire shutter doors and specialized fire door systems for different building sectors.
Complete Fire Door Product Range
LHSH supplies more than conventional steel fire doors. Its product portfolio also covers glazed fire doors, rail-transit fire doors, waterproof fire doors, explosion-resistant fire doors and steel-aluminum composite fire windows.
Project-Specific Manufacturing
● Custom dimensions
● Single, double and unequal leaves
● Customized vision panels
● RAL finishes
● Hardware preparation
● Customized frame configurations
Quality Management Systems
LHSH states that its operations follow ISO9001 and GB/T50430 quality management systems, ISO14001 environmental management requirements and GB/T28001 occupational health and safety management practices.
Full-Assembly Fire Testing
LHSH has published Intertek testing information for a fully glazed insulated steel composite fire door tested according to EN 1634-1:2014+A1:2018, helping project buyers evaluate a tested complete glazed doorset rather than relying only on the specification of individual glass components.
Commercial Fire Rated Glass Door FAQs
Can LHSH manufacture custom fire rated glass doors?
Yes. LHSH supports customized door dimensions, glazing arrangements, RAL colors, frame configurations and hardware preparation according to project requirements.
What fire ratings are available?
LHSH publishes EI30, EI60, EI90 and EI120 configurations across its current glazed fire door product range. Other fire durations should be confirmed according to the required standard and specific doorset configuration.
Can the glass size be customized?
Yes, but the size of fire-rated glazing cannot be treated as unrestricted customization. The final glass dimensions should comply with the tested or approved configuration for the required fire rating.
What is the difference between fire-rated glass and ordinary safety glass?
Ordinary tempered or laminated safety glass is designed mainly for impact safety and breakage behavior. Fire-rated glass is specifically engineered and tested for defined fire-resistance performance. Ordinary safety glass should not be substituted for certified fire-rated glazing in a rated opening.
Can LHSH supply the door frame and hardware?
Yes. LHSH glazed fire door specifications include steel frames and options for locks, handles, hinges, door closers, panic bars and other project-requested hardware.
What information is needed to get a quotation?
Send the fire rating, standard, opening dimensions, wall thickness, door configuration, glass requirements, hardware schedule, finish, quantity and destination. For commercial projects, a door schedule or architectural drawing is strongly recommended.
Request a Commercial Fire Rated Glass Door Solution
See All +
Reason to Choose Us
Customizable Solutions
LHSH, a leader in the fire safety industry since 1998, leverages decades of expertise, craftsmanship, and technological innovation to deliver high-quality, reliable products. Backed by the ISO 9001:2008 and GB/T50430-2007 systems, we ensure that every solution meets the highest standards of safety and design to serve the diverse needs of our clients.