No water protection needed:
unlike traditional steel shutters, inorganic composite shutters eliminate the need for water spray systems, saving water and reducing infrastructure costs.
In high-traffic office spaces and meeting rooms, fire safety is non-negotiable. Our fire-rated shutter doors provide critical compartmentalization,
slowing fire spread and ensuring safe evacuation, while blending seamlessly with modern office aesthetics.
Why Choose Our Fireproof Shutter Doors?
✔ 30/60/90-Min Fire Resistance – Tested & certified for compliance
✔ Sound Insulation – Reduces noise for distraction-free meetings
✔ Sleek & Professional Design – Customizable finishes (wood, steel, glass)
✔ Automatic Closing Mechanisms – Ensures doors shut safely during emergencies
✔ Smoke Seals & Intumescent Strips – Blocks toxic fumes for added protection
Perfect for:
- Corporate offices & coworking spaces
- Conference rooms & executive suites
- Server rooms & high-risk areas
Don’t Compromise on Safety! Upgrade to code-compliant, high-performance fire doors today.
Motorized Fire Door with Windows
Characteristics
FOR UNDERGROUND ROW GARAGES (MULTI-UNIT COMPLEXES)
IDEAL FOR APARTMENT BUILDINGS, CONDOS, AND COMMERCIAL PARKING, OUR FIRE-RATED ROLLING SHUTTERS OFFER COMPARTMENTALIZATION TO PREVENT FIRE SPREAD, PROTECTING MULTIPLE VEHICLES AT ONCE. BUILT WITH HEAVY-DUTY MATERIALS AND AUTOMATED CONTROLS.
FOR PRIVATE GARAGES (Ground Level)
DESIGNED FOR DURABILITY AND STYLE, OUR SHUTTERS PROVIDE ENHANCED SECURITY, FIRE RESISTANCE, AND INSULATION, ENSURING YOUR GARAGE STAYS PROTECTED AGAINST FLAMES, THEFT, AND EXTREME WEATHER. EASY TO OPERATE, LOW MAINTENANCE AND CUSTOMIZABLE TO FIT ANY DESIGN.
FOR WAREHOUSES & STORAGE FACILITIES
MINIMIZE FIRE RISKS AND SECURE HIGH-VALUE INVENTORY WITH INDUSTRIAL-GRADE FIREPROOF SHUTTERS. OUR SOLUTIONS ARE CERTIFIED FOR FIRE RESISTANCE, HEAT INSULATION, AND FORCED-ENTRY PROTECTION, ENSURING BUSINESS CONTINUITY AND ASSET SAFETY.
Certification Standard
EN16034: the overarching standard for pedestrian and industrial fire/smoke doors & shutters. it mandates assessment against:
EN 1634-1: fire resistance test for doors, shutters, and operable fabric curtains (integrity, insulation)
EN 1364-2: fire resistance tests for non-loadbearing elements - part 2: ceilings (relevant for shutter boxes/cassettes).
EN 1363-1/2: general fire resistance test methods.
EN 13501-2: classification using test data from above
UL 10B / UL 10C: standard fire tests for door assemblies.
UL 263: standard for fire tests of building construction and materials (similar scope to ASTM 119).
Technical data
FIRE RATING | > or =3–4 HOURS (TESTED TO GB9978/EN 1634) | TYPES, APPLICATIONS & BENEFIT | |
BACKFACE TEMPERATURE | AVG. > or =380°C; MAX. SINGLE POINT > or = 180°C | ① DUAL-TRACK DUAL-CURTAIN | |
CURTAIN THICKNESS | 10–20 MM (MULTI-LAYER: CERAMIC FIBER + FIREPROOF CLOTH) | LARGE MALLS, ATRIUMS, INDUSTRIAL ZONES | |
OPERATION SPEED | 2.5–6.4 M/MIN (ELECTRIC); 4–5 M/MIN (GRAVITY FALL) | AIR-LAYER INSULATION; NO WATER SPRAY | |
AIR GAP (DUAL CURTAINS) | 300 MM (OPTIMIZES THERMAL INSULATION) | ② WATER-MIST STEEL SHUTTER | |
SOUND INSULATION | UP TO 42 DB REDUCTION | HIGH-HUMIDITY AREAS (E.G., PARKING GARAGES) | |
MOTOR POWER | 0.25–1.5 KW (AC/DC OPTIONS) | RAPID COOLING; SMOKE SUPPRESSION | |
MAX. DIMENSIONS | WIDTH: < or = 60 FT (18.3 M); HEIGHT: < or = 40 FT (12.2 M) | ③ FOLDABLE LIFT-TYPE | |
STRUCTURAL REQUIREMENTS | IRREGULAR OPENINGS (E.G., ESCALATORS, CURVED WALLS) | ||
WALL STRENGTH | MUST SUPPORT 300–500 KG LOADS; CONCRETE/BRICK WALLS RECOMMENDED. | SPACE-SAVING; COLUMN-FREE DESIGN | |
OPENING TOLERANCE | ≤5 MM DEVIATION (PLUMB/LEVEL) FOR SEAMLESS TRACK ALIGNMENT. | ④ INSULATED STEEL (FIRESTAR) | |
APPLICATION | BUILDING PROJECT, COMPANY, HOME, OFFICE, HOTEL, CHURCH, JUST ANYWHERE YOU WANT! | EXTREME CLIMATES (E.G., COLD STORAGE) | |
PACKAGE | INSIDE: PE PAPER | OUTSIDE: DOUBLE LAYERS CARTON BOX AND WOODEN PALLETS. | MINERAL WOOL CORE; U-VALUE < or = 0.8 W/M²K |