Industrial-grade Fireproof Shutters

Industrial-grade Fireproof Shutters

Safeguard Your Facility with Heavy-Duty Fire & Security Solutions

View Products +
Home - Products - Fire Rolling Shutter - Fire Rolling Shutter - Best Fire Resistant Roller Door

Best Fire Resistant Roller Door

✨ THE INVISIBLE GUARDIAN: DEPLOYING SECURITY IN SECONDS.

Call to Action: Request a free fire safety audit and explore customized solutions for your project!

Target Applications & Marketing Angles

Industrial: Warehouses, factories, and logistics centers requiring compartmentalization for fire safety compliance. 

Commercial: Shopping malls, hospitals, and parking garages needing smoke control and crowd evacuation pathways. 

Residential: High-rise apartments and mixed-use buildings where space optimization and aesthetics are critical. 

Why Choose Our Fire Shutters? 

1. Global Compliance: Products certified for EU, US, and Asian markets. 

2. Turnkey Solutions: From design to installation and maintenance support. 

3. Cost-Efficiency: Reduce insurance premiums with certified fire protection. 

Best Fire Resistant Roller Door

Best Fire Resistant Roller Door

Characteristics

QUIET OPERATION

NOISE LEVELS <65 DB DURING OPENING/CLOSING. LOW WEIGHT (7 KG/M²): REDUCES BUILDING LOAD SIGNIFICANTLY, IDEAL FOR LARGE SPANS (E.G., ATRIUMS, SHOPPING MALLS) WHERE STRUCTURAL LOAD CAPACITY IS LIMITED.

AUTO-TRIGGER MECHANISMS

INTEGRATES WITH SMOKE/HEAT DETECTORS AND FIRE ALARM SYSTEMS FOR IMMEDIATE DESCENT DURING EMERGENCIES; INCLUDES THERMAL FUSE DEVICES FOR FAIL-SAFE CLOSURE. 

FOLDABLE LIFT-TYPE VARIANTS

 (E.G., U-SHAPED, CURVED) FIT IRREGULAR OPENINGS WITHOUT SUPPORT COLUMNS, MAXIMIZING ARCHITECTURAL FLEXIBILITY. 

VERTICAL OR HORIZONTAL ROLL-UP:ADAPTS TO TIGHT SPACES WITH MINIMAL OVERHEAD CLEARANCE. 


Certification Standard

EN16034: the overarching standard for pedestrian and industrial fire/smoke doors & shutters. it mandates assessment against:

EN 1634-1: fire resistance test for doors, shutters, and operable fabric curtains (integrity, insulation)

EN 1364-2: fire resistance tests for non-loadbearing elements - part 2: ceilings (relevant for shutter boxes/cassettes).

EN 1363-1/2: general fire resistance test methods.

EN 13501-2: classification using test data from above 

UL 10B / UL 10C: standard fire tests for door assemblies. 

UL 263: standard for fire tests of building construction and materials (similar scope to ASTM 119).

Technical data

FIRE   RATING> or =3–4   HOURS (TESTED TO GB9978/EN 1634)
TYPES, APPLICATIONS & BENEFIT
 BACKFACE TEMPERATUREAVG.   > or =380°C; MAX. SINGLE POINT > or = 180°C DUAL-TRACK DUAL-CURTAIN
CURTAIN THICKNESS10–20   MM (MULTI-LAYER: CERAMIC FIBER + FIREPROOF CLOTH)LARGE   MALLS, ATRIUMS, INDUSTRIAL ZONES
OPERATION SPEED2.5–6.4   M/MIN (ELECTRIC); 4–5 M/MIN (GRAVITY FALL)AIR-LAYER INSULATION;   NO WATER SPRAY
AIR GAP (DUAL CURTAINS) 300   MM (OPTIMIZES THERMAL INSULATION) WATER-MIST STEEL SHUTTER
SOUND INSULATIONUP   TO 42 DB REDUCTIONHIGH-HUMIDITY   AREAS (E.G., PARKING GARAGES)  
MOTOR POWER0.25–1.5   KW (AC/DC OPTIONS)RAPID COOLING; SMOKE   SUPPRESSION
MAX. DIMENSIONSWIDTH:   < or = 60 FT (18.3 M); HEIGHT: < or = 40 FT (12.2 M)  FOLDABLE LIFT-TYPE
STRUCTURAL   REQUIREMENTSIRREGULAR OPENINGS   (E.G., ESCALATORS, CURVED WALLS)
WALL STRENGTHMUST   SUPPORT 300–500 KG LOADS; CONCRETE/BRICK WALLS RECOMMENDED.  SPACE-SAVING;   COLUMN-FREE DESIGN
OPENING TOLERANCE≤5   MM DEVIATION (PLUMB/LEVEL) FOR SEAMLESS TRACK ALIGNMENT.   INSULATED   STEEL (FIRESTAR)
APPLICATIONBUILDING   PROJECT, COMPANY, HOME, OFFICE, HOTEL, CHURCH, JUST ANYWHERE YOU WANT!
EXTREME   CLIMATES (E.G., COLD STORAGE) 
PACKAGEINSIDE:   PE PAPER | OUTSIDE: DOUBLE LAYERS CARTON BOX AND WOODEN PALLETS.
MINERAL   WOOL CORE; U-VALUE < or = 0.8 W/M²K


Doors Overviews

Certified Protection:

Engineered to meet international standards (e.g., EN 16034, UL 10B/C), with fire ratings from 1 to 4 hours (Class A per GB14102). 

Heat-Activated Automation:

Automatically deploys upon detecting heat or smoke, integrating with fire alarm systems for instant response. 

Fireproof Core:

Filled with rock wool or ceramic fiber insulation to block flames and reduce heat transfer.

Durability & Structural Integrity 

Heavy-Duty Materials:

Constructed with galvanized steel or aluminum alloy slats, reinforced with steel guides for impact resistance. 

Corrosion Protection:

Powder-coated or anodized finishes ensure longevity in harsh environments (e.g., warehouses, parking garages). 

Wind Load Resistance: 

Tested to withstand high wind pressures (e.g., EN 12424 Class 5), ideal for industrial facilities. 

Smart & Automated Operation 

Multiple Activation Modes:

Choose from manual override, motorized control, or full automation via smoke detectors or central fire systems. 

Emergency Power Backup: 

Equipped with 24V battery backups for operation during power outages. 

Remote Monitoring: 

Optional IoT integration for real-time status alerts and control via mobile apps. 

Space-Saving & Versatile Design 

Vertical or Horizontal Roll-Up:

Adapts to tight spaces with minimal overhead clearance.  

Custom Sizes & Configurations:

Available for large openings (e.g., up to 10m wide × 6m high) and curved tracks. 

Aesthetic Options:

Standard colors (RAL codes) or custom prints to blend with architectural themes. 

RELATED SOLUTIONS

INDUSTRIAL FACILITIES

HEALTHCARE HOSPITAL

RESIDENTIAL BUILDINGS

GOVERNMENT INFRASTRUCTURE

TRANSPORTATION HUBS

COMMERCIAL COMPLEXES

CONTACT US NOW

  • RESIDENTIAL BUILDINGS
  • COMMERCIAL COMPLEXES
  • INDUSTRIAL FACILITIES
  • TRANSPORTATION HUBS
  • HEALTHCARE HOSPITAL
  • GOVERNMENT INFRASTRUCTURE

Cookies

By clicking“Allow All,” you agree to store cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.